AR6280 integrated chassis, 1*SRU slot, 4*SIC slot, 2*WSIC slot, 2*XSIC slot, 2*power slot
Huawei's next-generation NetEngine AR6000 series enterprise routers use high-performance multi-core processors and a nonblocking switching structure, helping to deliver higher forwarding performance than the industry average.
The NetEngineAR6000 also integrates functions such as SD-WAN, routing, switching, VPN, security, and MPLS, ensuring diversified andcloud-based services are fully supported.
| Item | Details |
| Description | AR6280 integrated chassis, 1*SRU slot, 4*SIC slot, 2*WSIC slot, 2*XSIC slot, 2*power slot |
| Part Number | 2115641 |
| Model | AR6280 |
| First supported version | V300R019C00 |
| Chassis height [U] | 2 U |
| Weight with packaging [kg(lb)] | 12 kg (26.45 lb) |
| Weight without packaging [kg(lb)] | 8.85 (19.51) |
| Number of service board slots | 8 |
| RPS input | Not supported |
| PoE | Not supported |
| IP rating | IP20 |
| MTBF [years] | 27.55 years |
| MTTR [hours] | 2 hours |
| Availability | 0.999992942 |
| Power supply mode | Pluggable AC/HVDC and pluggable DC |
| Number of power modules | 2 |
| Rated input voltage [V] | Rated AC input voltage: 100 V to 240 V, 50 Hz or 60 Hz |
| Rated DC input voltage: –48 V DC to –60 V DC | |
| Input voltage range [V] | Maximum AC input voltage: 90 V to 264 V, 47 Hz to 63 Hz |
| Maximum DC input voltage: –38.4 V DC to –72 V DC | |
| Maximum input current [A] | Depending on the power modules that is used |
| Maximum output power [W] | Depending on the power modules that is used |
| Redundant power supply | Double AC power modules (1+1 backup) |
| Double DC power modules (1+1 backup) | |
| Types of fans | Pluggable |
| Number of fan modules | 1 |
| Heat dissipation mode | Air cooling |
| Airflow | Left-to-right airflow |
| Noise at normal temperature (acoustic power) [dB(A)] | 54.2 dB(A) |
| Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
| NOTE: | |
| When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). | |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | < 5000 m (16404.2 ft.) |
| Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
| Overtemperature alarm | Supported |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | < 5000 m (16404.2 ft.) |
| Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
| Overtemperature alarm | Supported |