Your current location:Home > All Categories > HUAWEI SWITCHES > CE6800 Series

Huawei CE6881-48S6CQ-B Part#02352QGG

Description

CE6881-48S6CQ-B switch (48*10GE SFP+, 6*100GE QSFP28, 2*AC power modules, 4*fan modules, port-side exhaust)

Detailed description

Huawei CE6881-48S6CQ Switch Overview

The switch provides high performance and high port density on data center networks and high-end campus networks. it has advanced hardware architecture with 40GE/100GE uplink ports and high-density 10GE access ports. By using Huawei’s VRP8 software platform, CloudEngine 6881-48S6CQ supports extensive data center features and high stacking capabilities.

 Additionally, CloudEngine 6881 adopts flexible airflow design (front-to-back or back-to-front), and is able to work with CloudEngine 16800 or CloudEngine 12800 series data center core switches to build elastic, virtual, and high-quality 40GE/100GE full-mesh networks, meeting requirements of cloud computing data centers



02352QGF CE6881-48S6CQCE6881-48S6CQ switch (48*10GE SFP+, 6*100GE QSFP28, without fan and power modules)
02352QGG CE6881-48S6CQ-BCE6881-48S6CQ switch (48*10GE SFP+, 6*100GE QSFP28, 2*AC power modules, 4*fan modules, port-side intake)
02352QGH CE6881-48S6CQ-FCE6881-48S6CQ switch (48*10GE SFP+, 6*100GE QSFP28, 2*AC power modules, 4*fan modules, port-side exhaust)
ModelCloudEngine 6881-48S6CQ
Ports48 x 10GE SFP+ ports and 6 x 100GE QSFP28 ports
Physical specificationsDimensions (H x W x D)
TemperatureOperating temperature: 0°C to 40°C (32°F to 104°F) at altitude of 0-1800 m (0-5906 ft.)
Relative humidity5% RH to 95% RH, noncondensing
Altitude< 5000 m (16404 ft.)
Noise (sound pressure, 27°C)Back-to-front airflow: < 57 dBA
Front-to-back airflow: < 58 dBA
Power source typeAC/DC/HVDC
AC power inputRated input voltage range: 100 V AC to 240 V AC, 50/60 Hz
Maximum input voltage range: 90 V AC to 290 V AC, 47 Hz to 63 Hz
DC power inputRated voltage range: -48 V DC to -60 V DC
Maximum voltage range: -38.4 V DC to -72 V DC
Rated input current600 W AC&240 V DC power module (PAC600S12 series):
8 A (100 V AC to 240 V AC)
4 A (240V DC)
1000 W DC power module (PDC1000S12 series): 30 A (-48 V DC to -60 V DC)
1200 W high-voltage DC power module (PHD1K2S12 series): 8 A
Maximum power consumption349 W
Typical power consumption194 W (100% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, double power modules)
240 W (100% throughput, short-distance optical modules on all optical ports, double power modules)
Maximum heat dissipation1191 BTU/hr
Surge protectionPower module:
AC: 6 kV in common mode and 6 kV in differential mode
DC: 4 kV in common mode and 2 kV in differential mode
HVDC: 4 kV in common mode and 2 kV in differential mode
Heat dissipation modeAir cooling
AirflowFront-to-back or back-to-front, depending on the fan modules and power modules
Power module backup1+1 backup
Fan module backupThe device supports four pluggable fan modules that work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Hot swapSupported by all power modules and fan modules


+8618513271599